Zoll R Series Defibrillator - Manual defibrillator for sanitary use

Manufacturer: Customs Model: R Series _Features: Hospital use, the latest generation technology in support of CPR.


Defibrillators for hospitals and ambulances, Zoll R Series® manual defibrillator


The ZOLL® R Series® monitor-defibrillator offers physicians comprehensive support for resuscitation. This includes state-of-the-art technology to help you meet current guidelines for high-quality CPR, and also OneStep ™ electrodes that make resuscitation simpler and faster. In addition, to help ensure that the R Series is ready for resuscitation with Code-Ready®, it runs an automatic test every day.

The Zoll R Series defibrillator at the head of high-quality CPR


• CPR Dashboard ™ with Real CPR Help®: guides lifeguards with real-time visual and sound feedback on CPR quality measures. It displays screens with depth and frequency values ​​and visual indicators of decompression, as well as the exclusive perfusion performance indicator, Perfusion Performance Indicator ™.

• See-Thru CPR®: reduces the duration of pauses during CPR by filtering the CPR device so that lifeguards can see if an organized underlying rhythm developed without interrupting compressions.

Technical specifications of the Zoll R Series defibrillator


Size: 20,8 cm tall x 26,7 cm wide x 31,7 cm deep. Weight: 6,2 kg with OneStep ™ cable and SurePower ™ battery; 6,9 kg with pallets.
Power supplies: AC network power supply: 100 to 120 V CA (50 / 60 Hz), 220 to 240 V CA (50 Hz); Battery: rechargeable lithium-ion battery.
Low battery indicator: the message "LOW BATTERY" appears on the monitor when less than 15 minutes of ECG monitoring remain.
Design standards: meets or exceeds the applicable requirements of UL standards 60601, AAMI DF80, IEC 60601-2-4, EN 60601-2-25 and 60601-2-27.
Patient safety: all patient connections are electrically isolated.

Environmental characteristics: operating temperature: 0 ° C to 40 ° C; storage and transport temperature: -20 ° C to 60 ° C; humidity: 5% to 95% relative humidity, non-condensing; vibration: IEC 68-2-6 and IEC 68-2-34; download: IEC 68-2-27, 50 g 6 ms half-sine; Operating pressure: 594 to 1060 millibars; Water and particle inlet: IEC 529, IP22; Electromagnetic compatibility (CEM): CISPR 11 Class B Radiated and conducted emissions; electromagnetic immunity: AAMI DF80, IN 61000-4-3 to 10 V / m; electrostatic discharge: AAMI DF80, EN 61000-4-2; Susceptibility driven: IN 61000-4-4, 61000-4-5, 61000-4-6.

Defibrillator waveform: Rectilinear Biphasic. ™ Patient impedance interval: from 15 to 300 ohms.
Power selections: 1 to 10, 15, 20, 30, 50, 75, 100, 120, 150 and 200 joules that are selected by the controls located on the front of the defibrillator or on the sternum paddles. (Note: when appropriate electrodes are used for pediatric resuscitation, the 75 joules setting is replaced by the 70 and 85 joules settings).
Smart Step energy levels: energy is automatically increased by a protocol configured as adult or pediatric.

Energy display: both the selected and the applied energy appear on the monitor.

Charging time: less than 7 seconds with a new and fully charged battery (the first 15 charges to 200 joules). A longer charging time will be necessary for spent batteries
or older.

Synchronized mode: synchronizes the impulse of the defibrillator with the R wave of the patient. The message "SYNC" appears on the monitor and the markers are displayed both on the monitor and on the ECG
registered.

Load controls: control both from the front of the defibrillator and from the tip blade.
Pallets: external pallets for the tip / sternum; the plates for adults are removed by sliding to expose the surface of the electrode for pediatric use.
Preparation check for resuscitation: check the defibrillator hardware, the therapy application cable (with both the paddles and the electrodes), and the status and expiration date of the electrodes (with certain OneStep electrodes) without the need for any Additional accessory for testing.

ECG monitoring

Patient connection: 3 ECG lead leads, 5 ECG lead leads, pallets or hands-free electrodes, which can be selected using the front panel switch.
Protection of the entrance: completely protected from the defibrillator. Circuits designed to avoid distortion of the ECG signal due to pacemaker pulses.